Источник: http://www.iocellnetworks.com/support/helpdesk/windows/ndasErrorCodes/
Описание ошибок при подключении NDAS с официального сайта тех. поддержки IOCELL под катом:
Описание ошибок при подключении NDAS с официального сайта тех. поддержки IOCELL под катом:
0000FF13 () | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | |
Error Code | 0000FF13 () |
Message | An error occured while mounting an NDAS device as Read/Write Mode |
Explanation | Reported only once from Germany. User had several NDAS units. |
Symptom | Mounting failed, though there was a white square. Device worked previously. |
Problem | Hard disk was bad, even though only 4 weeks old. |
Correction | Replace Hard Disk. |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
0000FF14 () | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | |
Error Code | 0000FF14 () |
Message | An error occured while mounting an NDAS device as Read/Write Mode |
Explanation | |
Symptom | Attempting to access the device by NDAS Device Management or by drive letter produces the error. |
Problem | This is a very generic message. I only means the NDAS device is not communicating properly. |
Correction | Trey connecting the NDAS device by USB wire to see if the internal hard disk is functioning. Then try connecting the Ethernet cable directly to a PC and attempt to connect by NDAS. More than likely, the hard disk or NDAS device case has failed. |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
1 (0x0001) | |
Title | An error occured while mounting a NDAS device as Read/Write Mode |
Facility | NDAS 0x10000 |
Error Code | 1 (0x0001) |
Message | Communication to the NDAS service failed. |
Explanation | NDAS Service is the core component that watches over the NDAS devices. It can fail if LPX Protocol is not installed or if the start up setting is incorrect. There may be other reasons as well. |
Symptom | Attemping operations on the NDAS Device Management Menu will fail producing the error. |
Problem | NDAS Serivce has not started for some reason. |
Correction | Manual start up: From XP: click the start button, choose Run, then type services.msc in the box and click OK. Vista or Win7: Click the start button, then type services.msc in the search box and hit enter. Now find the NDAS Service and see that the status is Started and that Startup type is Automatic You can right click and choose properties to change any of these settings. Even if it is started, please try to stop and restart this service, if you are having communication problems. |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Exit, Options, About NDAS, Refresh Status, Register a New Device |
4 (0x0004) | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | NDAS 0x20000 |
Error Code | 4 (0x0004) |
Message | Communication error during login process |
Explanation | |
Symptom | Mounting 2nd bay on 352nd failed |
Problem | Bad chipset? Error was followed by 35 / NDAS logical device entry not found on retry |
Correction | |
USB Works? | No |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
6 (0x0006) | |
Title | The requested operation has not succeeded |
Facility | NDAS 0x0003 |
Error Code | 6 (0x0006) |
Message | Invalid parameter. |
Explanation | There were changes to the NDAS software related to RAID units in Vista and Windows 7. |
Symptom | Attempting to create a RAID configuration produces the error message and the RAID creation fails. The disks will mount individually without any problem. |
Problem | RAID with NDAS firmware 1.0 and below only works with NDAS 3.30 or earlier |
Correction | Use an earlier NDAS Software version, use file system level mirroring software, mount to a single host and share... |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Mount RW, Mount RO |
18 (None) | |
Title | Disk Drive (Unrecognized Type 0000) |
Facility | None |
Error Code | 18 (None) |
Message | in Unit Device Information Disk Drive (Unrecognized Type 0000) |
Explanation | Error appears only in the NDAS Device Properties |
Symptom | The internal hard drive spins down immediately, in the IOCELL 351UNE (B) when any data connector (USB/eSATA/Ethernet) is attached. |
Problem | Manufacturing defect |
Correction | Replace Unit |
USB Works? | No |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
21 (None) | |
Title | Disk Drive (Unrecognized Type 0000) |
Facility | None |
Error Code | 21 (None) |
Message | Disk Drive (Unrecognized Type 0000) |
Explanation | |
Symptom | Finish registration and cannot access the drive |
Problem | Unknown hardware incompatibility or broken hard disk |
Correction | Replaced Maxtor 160GB with Seagate 80GB and it works. |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Error, Reset, Deregister, Properties |
35 (0x0023) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x100000 |
Error Code | 35 (0x0023) |
Message | NDAS Logical Device Entry Not Found |
Explanation | There is a conflict between NDAS Software Versions 3.4.x and NDAS Hardware version 1.0 or lower. This is especially prevalent when running from a Vista Computer and operating a multi-disk configuration. But it may affect other operating systems and single disk set ups a well. Please download and install driver version 3.2 on all the machines that connect to the NDAS device. Or upgrade the device. |
Symptom | Retry to Mount Disk Fails |
Problem | Hardware version conflicts with NDAS Software Version |
Correction | Remove the conflicting driver, install compatible version. |
USB Works? | Can |
Icon Color | Black |
Icon Changes | Red |
NDAS Menu Options | Mount RO, Mount RW, Deregister, Reset |
35 (0x0023) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x100000 |
Error Code | 35 (0x0023) |
Message | NDAS Logical Device Entry Not Found |
Explanation | NDAS chipsets manufactured prior to December 2004 have a 250 GB size limit. The first 3 numbers of the unit serial number reveal the date of year and month of manufacture. If the serial number begins with N the following number represents the year it was made and the next two number represent the month. Devices manufacture from January 2005 do not have such disk size limitations. |
Symptom | Retry to Mount Disk Fails |
Problem | Hard Disk is too large for the NDAS chipset |
Correction | Replace the drive with a smaller unit. |
USB Works? | Can |
Icon Color | Black |
Icon Changes | Red |
NDAS Menu Options | Mount RO, Mount RW, Deregister, Reset |
35 (0x0023) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x100000 |
Error Code | 35 (0x0023) |
Message | NDAS Logical Device Entry Not Found |
Explanation | |
Symptom | Retry to Mount Disk Fails |
Problem | LPX Protocol is not installed |
Correction | Install the LPX Protocol |
USB Works? | Can |
Icon Color | Black or White |
Icon Changes | Black |
NDAS Menu Options | Offline, Deregister, Properites |
35 (0x0023) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode |
Facility | NDAS 0x10000 |
Error Code | 35 (0x0023) |
Message | NDAS Logical Device Entry Not Found |
Explanation | None. The disk management utility does not know the drive is offline |
Symptom | After seeing error 468803 clicked the retry button, and saw the 35 error |
Problem | NetDisk was physically disconnected from the LAN |
Correction | Choose Properties, Advance, Reset Connection and icon became black |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Deregister, Properties |
66 (0x0042) | |
Title | An error occured while mounting a NDAS device as read only mode |
Facility | NDAS 0x100000 |
Error Code | 66 (0x0042) |
Message | Some NDAS logical device members are missing in the entry |
Explanation | |
Symptom | Cannot Mount Options Grayed out |
Problem | Raid Information Incompatible with Driver Version |
Correction | Choose Migrate or reset from Bind Manager |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Properties |
73 (0x0049) | |
Title | An error occured while mounting a NDAS device as read only mode |
Facility | NDAS 0x100000 |
Error Code | 73 (0x0049) |
Message | The bind information in NDAS device is changed. |
Explanation | Reported by Dr. Singh, who installed NDAS to another PC and found the disks working. Then debugged the source. |
Symptom | NetDisk does not mount RO |
Problem | There was corrupted communication from the PC to the NetDISKs, caused by Anti-SpyWare program. |
Correction | Change Anti-Spyware program "Spyware Terminator" |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
82 (0x0052) | |
Title | |
Facility | NDAS 0x10000 |
Error Code | 82 (0x0052) |
Message | An error occurrred while mounting and NDAS device as Read/Write Mode. |
Explanation | NDAS logical device is not in a mountable status |
Symptom | Mounting had failed with error 458839 |
Problem | The miniport of the device was disabled when the drive was mounted. |
Correction | Enable the miniport controller |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Mount RW RO Properties |
103 (0x0067) | |
Title | An error occured while mounting a NDAS device... |
Facility | NDAS |
Error Code | 103 (0x0067) |
Message | The NDAS device ID cannot be used with the current version of the software. Upgrade the software to the most recent version or use the vendor-provided software. |
Explanation | Even gathering the MAC address will not permit ID calculation. We do not know the former vendor codes. |
Symptom | Device may be recognized, (NDAS PnP) but registration will fail. |
Problem | The NDAS ID can be calculated to include a vendor ID. The PnP wizard will not detect it. |
Correction | The vendor must provide the correct code. |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
104 (0x0068) | |
Title | An error occured while mounting a NDAS device as read only mode |
Facility | |
Error Code | 104 (0x0068) |
Message | |
Explanation | Unknown defect |
Symptom | Requested Operation Could Not Be completed while the drive is connecting. |
Problem | Hardware failure. |
Correction | User reported replacement is working fine. 2 reports |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
112 (0x0070) | |
Title | An error occured while mounting a NDAS device as read/write mode |
Facility | NDAS 0x100000 |
Error Code | 112 (0x0070) |
Message | The NDAS logical unit cannot use required NDAS units to complete the operation. For fault-tolerant RAID sets, you can mount it in degrade mode without all members. You should use NDAS Bind Management to mark the RAID set in degrade mode before you mount it. |
Explanation | |
Symptom | After 460212 while trying to mount a raid in the 352ND |
Problem | One of the NDAS devices or drive bays included in the raid setup is not functioning. |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
112 (0x0070) | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | 0x0010 |
Error Code | 112 (0x0070) |
Message | The NDAS logical unit cannot use the require NDAS units to complete the operation. For fault-tolerant RAID sets, you can mount it in degrade mode without all members. You should use NDAS Bind Management to mark the RAID set in degrade mode before you mount it. |
Explanation | The internal disk was a member of a RAID configuration. But the other members are not available. |
Symptom | Failed to mount |
Problem | A RAID member is missing |
Correction | If RAID was 1 (Mirror) Mount in degrade mode from the bind manager. If not, reformat or get professional recovery help. |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
10022 (0x2726) | |
Title | The requested operation has not succeeded |
Facility | |
Error Code | 10022 (0x2726) |
Message | An invalid argument was supplied |
Explanation | |
Symptom | Mounting a former member of a mirror to the mirror does not work. |
Problem | |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
458752 () | |
Title | |
Facility | |
Error Code | 458752 () |
Message | |
Explanation | |
Symptom | Mounts but does not appear in my computer |
Problem | |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
458752 () | |
Title | |
Facility | |
Error Code | 458752 () |
Message | |
Explanation | |
Symptom | Tries to mount but fails |
Problem | |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
458839 (0x70057) | |
Title | An error occured while mounting as read only mode |
Facility | |
Error Code | 458839 (0x70057) |
Message | One or more arguments are invalid |
Explanation | |
Symptom | Was mounted but autoplay crashed. Lost connection. Remount and error appeared |
Problem | |
Correction | Changed HD and it worked |
USB Works? | |
Icon Color | |
Icon Changes | White |
NDAS Menu Options |
458839 (0x0057) | |
Title | An error occurrred while mounting and NDAS device as Read/Write Mode. |
Facility | |
Error Code | 458839 (0x0057) |
Message | The parameter is incorrect |
Explanation | |
Symptom | Saw white sqaure tried to mount, but unsuccessful |
Problem | The miniport of the device was disabled when the drive was mounted. |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
459011 (0x70103) | |
Title | NDAS Device cannot be found |
Facility | |
Error Code | 459011 (0x70103) |
Message | |
Explanation | For an unknown reason, possibly the presence of Norton 360, the NDAS Bus connection device was not installed on the computer. |
Symptom | NetDisk is does not mount from the network. |
Problem | The NDAS Bus was never installed. |
Correction | Install the NDAS Bus via the Control Panel Add New Hardware wizard |
USB Works? | Can |
Icon Color | White |
Icon Changes | |
NDAS Menu Options | Mount RO, Mount RW, Deregister, Reset |
459011 (0x70103) | |
Title | |
Facility | |
Error Code | 459011 (0x70103) |
Message | An error occurrred while mounting and NDAS device as Read/Write Mode. |
Explanation | |
Symptom | Saw white sqaure tried to mount, but unsuccessful |
Problem | The NDAS Bus was disabled when the drive was mounted |
Correction | Enable the NDAS Bus |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Mount RW RO Properties |
460212 (0x705B4) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x100000 |
Error Code | 460212 (0x705B4) |
Message | NDAS Logical Device Entry Not Found |
Explanation | There is a conflict between NDAS Software Versions 3.4.x and NDAS Hardware version 1.0 or lower. This is especially prevalent when running from a Vista Computer and operating a multi-disk configuration. But it may affect other operating systems and single disk set ups a well. Please download and install driver version 3.2 on all the machines that connect to the NDAS device. Or upgrade the device. |
Symptom | Cannot Mount Disk Manually |
Problem | Hardware version conflicts with NDAS Software Version |
Correction | Remove the conflicting driver, install compatible version. |
USB Works? | Can |
Icon Color | Black |
Icon Changes | Black |
NDAS Menu Options | Mount RO, Mount RW, Deregister, Reset |
460212 (0x705B4) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x100000 |
Error Code | 460212 (0x705B4) |
Message | NDAS Logical Device Entry Not Found |
Explanation | NDAS chipsets manufactured prior to December 2004 have a 250 GB size limit. The first 3 numbers of the unit serial number reveal the date of year and month of manufacture. If the serial number begins with N the following number represents the year it was made and the next two number represent the month. Devices manufacture from January 2005 do not have such disk size limitations. |
Symptom | Cannot Mount Disk Manually |
Problem | Hard Disk is too large for the NDAS chipset |
Correction | Replace the drive with a smaller unit. |
USB Works? | Can |
Icon Color | Black |
Icon Changes | Black |
NDAS Menu Options | Mount RO, Mount RW, Deregister, Reset |
460212 (0x705B4) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | NDAS 0x705B4 |
Error Code | 460212 (0x705B4) |
Message | none |
Explanation | |
Symptom | Fails to Mount for a long time |
Problem | Attempted to mount the drive too soon after it was dismounted. |
Correction | Power down the NetDisk, wait until the NDAS manager Icon turns to black. Then turn on the NetDisk. Choose reset connection. When it finishes refreshing, see if the Mount RO & Mount RW options have returned. |
USB Works? | Can |
Icon Color | Grey |
Icon Changes | Black |
NDAS Menu Options | Deregister |
468774 (0x72726) | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | |
Error Code | 468774 (0x72726) |
Message | An error occured while mounting an NDAS device as Read/Write Mode |
Explanation | |
Symptom | |
Problem | |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
468795 (0x7273B) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode. |
Facility | |
Error Code | 468795 (0x7273B) |
Message | |
Explanation | |
Symptom | NetDisk does not mount RW |
Problem | LPX Protocol is not installed |
Correction | |
USB Works? | Wor |
Icon Color | White or Black |
Icon Changes | Black |
NDAS Menu Options | Offline, Deregister, Properites |
468803 (0x72743) | |
Title | An error occurred while mounting an NDAS device as Read/Write Mode |
Facility | |
Error Code | 468803 (0x72743) |
Message | An error occurred while mounting an NDAS device as Read/Write Mode |
Explanation | none, retry and found error 35 Logical entry not found |
Symptom | Saw white sqaure tried to mount, but unsuccessful |
Problem | Had previously taken unit offline, but refresing status did not change the icon color |
Correction | Choose Properties, Advance, Reset Connection and icon became black |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
468803 (0x72743) | |
Title | An error occured while mounting an NDAS device as Read/Write Mode |
Facility | None |
Error Code | 468803 (0x72743) |
Message | An error occured while mounting an NDAS device as Read/Write Mode |
Explanation | none, retry and found error 35 Logical entry not found, chose cancel and square was red |
Symptom | Saw white square tried to mount, but unsuccessful |
Problem | (Dr. Singh) There was corrupted communication from the PC to the NetDISKs, caused by Anti-SpyWare program. |
Correction | Change Anti-Spyware program, Second Report using PC Tools Firewall |
USB Works? | Yes |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Mount RW RO, Dergister, Properties |
468803 (0x72743) | |
Title | An error occurred while mounting and NDAS device as Read/Write Mode |
Facility | |
Error Code | 468803 (0x72743) |
Message | |
Explanation | |
Symptom | Attempted to mount NDAS device after seeing the white square |
Problem | The device was physically disconnected from the LAN at the time of trying to mount. Had refreshed status but the white icon did not change. |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options | Mount RW, RO |
4688803 (0x72743) | |
Title | |
Facility | |
Error Code | 4688803 (0x72743) |
Message | Connect to the following NDAS device has been lost. |
Explanation | |
Symptom | |
Problem | |
Correction | |
USB Works? | |
Icon Color | |
Icon Changes | |
NDAS Menu Options |
Комментариев нет: